You re simply checking for a continuous path on a ground circuit.
Electrical ground testing procedure.
Ground continuity testing ground continuity testing is the same concept as ground bond testing.
Insert 2 ground probes into the ground.
The procedures for earth resistance testing are referenced in ieee standard no.
An illustration from the us nbs 1918 procedure for electrical ground testing.
Download paper c the four potential method wenner method this technique helps overcome some of the problems associated with the requirement for knowing the electrical centre of the earthing systems being tested.
Testing procedures have been also developed.
On modern electrical systems rcd s and rcbo s are regularly fitted these devices react to electricity missing from the circuit or installation such as when a person is receiving an electric shock as the electricity passes through his body to the ground earth.
Inadequate electrical grounding or wiring on the customer s premises or.
The 3 point test requires complete isolation from the power utility.
Prior to about 15 years ago the basic methodology for ground testing remained fundamentally unchanged since it was originally devised in the early 20th century.
Purpose method a dc low current test to check circuit resistance.
Not just power isolation but also removal of any neutral or other such ground.
Four of the most common methods of ground resistance testing used by test technicians are discussed below.
In areas where driving ground rods may be impractical the two point method can be used.
The ground probes need to be inserted into the ground at specific distances away from the ground rod.
The furthest ground probe needs to be at a distance that is 10 times the length of the ground rod.
Similar concept to the ground bond testing.
The first is the 3 point or fall of potential method and the second is the induced frequency test or clamp on method.
Neta world techtips ground testing in difficult installations by jeffrey r.
Ground testing is used to measure the performance of this circuit and check if it meets requirements.
The end user would use a test instrument and probes to first inject a current into the earth between a test electrode and a remote probe measure the voltage drop caused by the soil to a designated point and then use ohm s law to.
Beyer wally electrical protetion grounding fundamentals pdf 1994 u s.
Electrical circuits have a separate ground or earth circuit that provides an alternate low impedance path for electricity to safely reach the ground in case of accidental physical contact.
However there are key differences between these two tests.
For instance if the ground rod is 8 feet 2 4 m long the furthest probe should be 80 feet 24 m away.
Department of agriculture usda rea bulletin 1751f 802.
2 point dead earth method.